Figure 13 - Outside air connection
* If you want to install it outside the house, you must purchase the outside air intake
kit.
* For Ø80mm air inlet kit - PA1090G035 (only for Urano Eco 60, Siena Eco 60, Hera
Eco 60 and Star Eco 60 models). For Ø100mm air inlet kit - PA1090G057.
* To make this connection, you must use the flexible hose from the air intake of the
unit to the outside of the house.
6.4.2. Additional outlets
* In the upper part of these equipment’s there are 2 exits (corresponding to a diameter
of 100 mm each), Figure 14, which can be used by removing the covers and adapting
ducts for conducting the hot air to other rooms.
* If the warm air duct always runs upwards, there is no need for a forced system. If it
is for distributing the heat, you should install an aspirator to force the air to circulate.
In this case, it should be installed as plumb over the unit as possible, so the thermostat
can detect the rising heat immediately.
* An air outlet grille should be placed in each room and all the ducts should be well
insulated.